Delivery
Break out FF material and disposal of it in accordance to legal regulations
Dismantling of the inductor Damage assessment – Repair channel furnace housing
Cleaning of housing
Flushing of housing cooling with special solution
Pressure test and painting of housing
Lining the inside of the housing with Isoplan Damage assessment – Repair of transformer core
Cleaning of the core and check of the billet insulation
Replacement of defective insulation
Checking of tensions, aligning and painting the core Damage assessment – Repair of coil cylinder
Cleaning of the cylinder and the cooling channel of the cooling profile with a special solution; determination of the water flow
If necessary, re-align cylinder
Pressure test for tightness of the cooling profile
Rework water connections; renewal cylinder insulation Damage assessment – Repair of channel furnace coils
Cleaning of coil shell
Cleaning of the cooling channel of the coil profile with a special solution
Determination of the flow rate
Rework connections, insulate coil, soak, oven dry Installation and delivery
Put the coil on the core
Checking of spacers
Installation of protective cylinder
Installation and aligning of the core in the housing
Final inspection and creation of test report - Delivery